HP Integrity rx2800 i2 Installation Manual

HP Integrity rx2800 i2 Installation Manual

Hide thumbs Also See for Integrity rx2800 i2:

Advertisement

Quick Links

Pedestal Kit Installation Guide for HP
Integrity rx2800 i2 and HP Proliant DL380
G6 & DL385 G6 Servers
HP Part Number: AM251-9000A
Published: January 2010
Edition: 1

Advertisement

Table of Contents
loading

Summary of Contents for HP Integrity rx2800 i2

  • Page 1 Pedestal Kit Installation Guide for HP Integrity rx2800 i2 and HP Proliant DL380 G6 & DL385 G6 Servers HP Part Number: AM251-9000A Published: January 2010 Edition: 1...
  • Page 2 Legal Notices The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP...
  • Page 3: Table Of Contents

    Table of Contents Abstract..........................5 Intended audience..........................5 1 Important warnings......................7 Electricity..............................7 Electrical grounding..........................7 Static electricity..........................7 Potential metallic particulate contamination..................7 2 Installing the server into the pedestal kit..............9 Required tools............................9 Remove the rails from the server......................9 Attach the pedestal kit top and bottom....................10 Attach the bezel cover...........................12 Attach the pedestal kit side pieces......................13 Attach the pedestal feet.........................15...
  • Page 4 List of Figures Removing the rails from the server....................9 Front of server..........................10 Installing the pedestal bottom piece....................11 Attaching the bezel Cover......................12 Attaching the pedestal kit side piece.....................13 Thumb screw locations........................14 Attaching the feet..........................15 Removing the pedestal kit feet......................17 Thumbscrew locations........................18 Removing the side piece........................18 Access panel removal........................19 Removing the pedestal kit feet......................21...
  • Page 5: Abstract

    Abstract This document describes how to convert the HP Integrity rx2800 i2 and HP Proliant DL380 G6 & DL385 G6 servers from a rack system to a pedestal system. The document printing date and part number indicate the document’s current edition. The printing date changes when a new edition is printed.
  • Page 7: Important Warnings

    1 Important warnings Electricity Electrical grounding WARNING! For your safety always connect the equipment to a grounded wall outlet. Always use a power cord with a properly grounded plug, such as the one provided with the equipment, or one in compliance with your national safety standards.
  • Page 9: Installing The Server Into The Pedestal Kit

    2 Installing the server into the pedestal kit Required tools There are no tools required for installing the pedestal kit. Remove the rails from the server If your server has rails when you receive it, you need to remove the rails before mounting it in the pedestal kit.
  • Page 10: Attach The Pedestal Kit Top And Bottom

    Attach the pedestal kit top and bottom IMPORTANT: In this document the server top, bottom, right and left always refer to the server as faced from the front with the server in a horizontal orientation. The pedestal kit components are referred to by their final position with the server in a vertical orientation.
  • Page 11: Installing The Pedestal Bottom Piece

    NOTE: The bottom piece of the pedestal is taller than the server, so try to position the server so the right side (in the horizontal position) of the server hangs off the edge of the work surface by a few inches to allow the bottom piece to be attached to the server chassis. If that is not possible, then raise up the server approximately 3 inches from the work surface to allow the pedestal kit bottom piece to be attached to the server left side.
  • Page 12: Attach The Bezel Cover

    Attach the bezel cover To attach the bezel cover: Attach the bezel cover to the front of the server starting from the bottom of the pedestal kit. Push the bezel cover into place against the pedestal kit top piece until the tabs on the bezel cover snap into place.
  • Page 13: Attach The Pedestal Kit Side Pieces

    The ventilation holes in the pedestal kit right side piece must be matched up with the ventilation holes on the top cover of the HP Integrity rx2800 i2 server to allow for proper cooling and air flow. Failure to heed this warning will cause the server to shut down with an overtemp condition.
  • Page 14: Thumb Screw Locations

    Secure the pedestal side by hand tightening the captive thumb screws on the rear of the server. Figure 2-6 Thumb screw locations Repeat these steps to install the left side piece. Installing the server into the pedestal kit...
  • Page 15: Attach The Pedestal Feet

    Attach the pedestal feet The pedestal feet slide into the slots on the pedestal bottom, two on each side. The feet are all the same and can be mounted in any slot on the bottom piece of the pedestal kit. Figure 2-7 Attaching the feet Attach the pedestal feet...
  • Page 17: Accessing Internal Components

    3 Accessing internal components To access internal components on a pedestal-mounted server: Power down the server and remove all cables. Remove the pedestal kit feet. Figure 3-1 Removing the pedestal kit feet Lay the server on the left side (facing the front of the server). The right side of the pedestal kit (with the ventilation holes) should be facing up.
  • Page 18: Thumbscrew Locations

    Figure 3-2 Thumbscrew locations Slide the right side pedestal kit piece toward the back of the server, and lift up on the piece to remove it from the pedestal. Figure 3-3 Removing the side piece Accessing internal components...
  • Page 19: Access Panel Removal

    Remove the server access panel. Figure 3-4 Access panel removal The server is ready for servicing. Once servicing is complete, do the following to put the pedestal kit back on the server. Close the access panel. Install the right side pedestal piece. Tighten the thumbscrews on the rear of the server.
  • Page 21: Removing The Server From The Pedestal Kit

    4 Removing the server from the pedestal kit Required tools No tools are required for disassembling the pedestal kit. Power off the server and remove cables Power down the server using the instructions provided in the server service guide. Disconnect the power and LAN cables connected to the server. Removing the pedestal kit Remove pedestal feet.
  • Page 22: Thumbscrew Locations

    Figure 4-2 Thumbscrew locations Figure 4-3 Removing the side piece Release the locking tabs behind the top corners of the bezel cover and remove the component. Removing the server from the pedestal kit...
  • Page 23: Removing The Bezel Cover

    Figure 4-4 Removing the bezel cover Remove the pedestal top piece. With the server still in the vertical position, look at the left side of the server (server bottom) to locate the lock release tab. Press the lock release tab on the pedestal top piece away from the chassis to unlock the pedestal top piece from the server.
  • Page 25: Support And Other Resources

    AM251-9000A January 2010 Related information The latest versions of these documents, including any updates, are posted at: http://www.hp.com/ go/Integrity_Servers-docs and http://www.hp.com/go/Proliant_Servers-docs. The Rack System /E User's Manual can be found at: http://www.hp.com under Enterprise Rack & Power Products. Typographic conventions...
  • Page 27: Index

    Index access panel warnings removal, 19 electrical, 7 metallic particulate contamination, 7 static electricity, 7 bezel cover attaching, 12 removal, 22 zinc whiskers (see metallic particulate contamination) electricity grounding, 7 static, 7 internal components accessing, 17 metallic particulate contamination, 7 pedestal bottom attaching, 10 removal, 23...
  • Page 28 *AM251-9000A* Printed in the US...

This manual is also suitable for:

Proliant dl380

Table of Contents