Troubleshooting; How To Contact Hp; Methodology; General Troubleshooting Methodology - HP Integrity rx2800 i4 User Manual

Hp integrity server
Hide thumbs Also See for Integrity rx2800 i4:
Table of Contents

Advertisement

6 Troubleshooting

The purpose of this chapter is to provide a preferred methodology (strategies and procedures) and
tools for troubleshooting the server error and fault conditions.

How to contact HP

For information on how to contact HP, see

Methodology

General troubleshooting methodology

There are multiple entry points to the troubleshooting process, dependent upon your level of
troubleshooting expertise, the tools/processes/procedures which you have at your disposal, and
the nature of the system fault or failure.
Typically, you select from a set of symptoms, ranging from very simple (system LED is blinking) to
the most difficult (Machine Check Abort (MCA) has occurred. The following is a list of symptom
examples:
NOTE:
Your output might differ from the output in the examples in this book depending on your
server and its configuration.
Front panel LED blinking
System alert present on console
System will not power-up
System will not boot
Error/Event Message received
Machine Check Abort (MCA) occurred
Narrow down the observed issue to the specific troubleshooting procedure required. Isolate the
failure to a specific part of the server, so you can perform more detailed troubleshooting. For
example:
Issue- Front panel LED blinking
NOTE:
a fault indication.
System Alert on console?
Analyze the alert by using the system event log (SEL) and forward progress log (FPL), to
identify the last error logged by the server. Use the iLO 3 MP commands to view the SEL
and FPL, either through the iLO 3 MP serial text interface, or through Secure Shell, or
through the web GUI on the iLO 3 MP LAN.
You can now determine which area of the system requires further analysis. For example, if the
symptom was "system will not power-up", the initial troubleshooting procedure might indicate a
issue with the DC power rail not coming up after the power switch was turned on.
You have now reached the point where the failed CRU has been identified and needs to be
replaced. Perform the specific removal and replacement procedure, and verification steps.
NOTE:
If multiple CRUs are identified as part of the solution, a fix cannot be guaranteed unless
all identified failed CRUs are replaced.
HP Confidential
The front panel health LEDs flash amber with a warning indication, or flash red with
"Contacting HP" (page
132).
How to contact HP
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Integrity rx2800 i4Integrity rx2900 i4

Table of Contents