HP Integrity rx2800 i4 User Manual page 67

Hp integrity server
Hide thumbs Also See for Integrity rx2800 i4:
Table of Contents

Advertisement

Figure 23 System Insight Display LEDs
Table 17 SID LED states
LED
NICs
Power Cap
Over Temp
System Event Log
Component LEDs
The System Insight Display improves serviceability by enabling you to look in a single location for
the LEDs that provide failing CRU locating/mapping information. These amber LEDs are only lit
when a failure occurs; otherwise, they are off. The System Insight Display is located on the front
HP Confidential
State
Off = No link to network
Flashing green = Network link and activity
Green = Network link
Capping
Power
On
On
On
Off
Off
On
Off
Off
NOTE:
Power capping operation can be observed
through iLO 3 also. For more information, see the HP
Integrity iLO 3 Operations Guide.
Off = Server temperature good
Amber = Server temperature too high, attention required
Green = Normal
Red = System fatal
Off = Component health is assumed good
Amber = Component health last known to be bad
NOTE:
The Power Supply LED is lit only when a failure
or fault is detected in a power supply. Loss of AC power
to a power supply generates a SEL entry, but does not
result in the Power Supply LED becoming lit.
LED
Green
Off
Off
Off
Troubleshooting tools