Output locations
Introduction
If a stack of folded sheets is too high, the stack will tilt. Therefore, the system limits the
number of folded sheets per output location. How the system limits the output capacity
depends on the folding method.
Z-fold
•
Depends on media weight and type.
•
Depends on the percentage of folded sheets in a stack.
Half-fold
•
Determined by a fixed number of folded sheets.
The default settings guarantee safe stacking for media up to 100 g/m² or 27 lb. bond for
plain media or 120 g/m² or 32 lb. bond for coated media. You can adjust the stack height
for heavier media in the Settings Editor. You can change the stack height in increments
of 10% from -50% to +200%. For heavier media, start with -50% to prevent stacks tilting.
The table below gives an overview of the default capacity per output location for half-
folded and Z-folded sheets.
Z-fold
Output capacity for Z-folded sheets
Percentage of
folded sheets
(%)
1
2
3
5
10
14
25
#
Stacker (number of sheets)
6000
3200
1980
1080
400
280
160
Chapter 6 - Optional finishers and other devices
Output locations
Finisher (number of sheets)
4000
3000
2250
1320
510
273
144
203