NEC Express 5800 User Manual page 403

Express5800 series
Hide thumbs Also See for Express 5800:
Table of Contents

Advertisement

(4)
Miscellaneous
Display/set other setting information.
Property
Maintenance Mode
Core Status RAS Mode
Maximum Ambient
Temperature
*1 It is possible to use the server under 40°C when the server applies the BMCFW and BIOS
supporting the condition and does not have HDD#1,#4,#7,#10,SAS RAID BBU and external
SAS RAID controller. If any HDD is mounted on those slots, replace it with "Disk Dummy
Tray", NE3105-901.
Also set Maximum Ambient Temperature as 40 degrees C to use under 40°C.
The servers shipped after March in 2012 apply the BMCFW and BIOS by default.
Consult with maintenance personnel of the maintenance service company for applying the
required BMCFW and BIOS to the server if necessary.
Description
Enable or disable the maintenance mode.
This mode is used when customer engineer
works for the server maintenance.
The Customer engineer sets this mode enable
before starting maintenance, and sets needed
maintenance times (settable In maintenance
mode, the icon
upper side. Customer does not need set this
mode.
⁃ Default
maintenance
mode):0 minute
⁃ Default
maintenance
mode):6 minutes
Enable or disable RAS functionality.
⁃ Disable : Core RAS functionality is enable
⁃ Enable : Core RASfunctionality is disable
If this mode is valid and the system has one or
more alternative cores in the system, the
management firmware disabled the processor
core at processor core failure. And the
Managemnt foemware reconfigure the server
resource.
Select the Maximum upper value for Ambient
Temperature monitoring
⁃ 35 degrees C
⁃ 40 degrees C(*1)
This setting will be applied after the server reset.
403
will appear on right of
time
(at
Disabled
time
(at
Enabled
Default
setting
Disable
Enable
35 degrees C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents