38.3.2 Supported MIBs

MIBs let administrators collect statistics and monitor status and performance.
The Switch supports the following MIBs:
• SNMP MIB II (RFC 1213)
• RFC 1157 SNMP v1
• RFC 1493 Bridge MIBs
• RFC 1643 Ethernet MIBs
• RFC 1155 SMI
• RFC 2674 SNMPv2, SNMPv2c
• RFC 1757 RMON
• SNMPv2, SNMPv2c or later version, compliant with RFC 2011 SNMPv2 MIB for IP, RFC 2012
SNMPv2 MIB for TCP, RFC 2013 SNMPv2 MIB for UDP

38.3.3 SNMP Traps

The Switch sends traps to an SNMP manager when an event occurs. The following tables outline the
SNMP traps by category.
An OID (Object ID) that begins with "1.3.6.1.4.1.890.1.5.8" is defined in private MIBs. Otherwise,
it is a standard MIB OID.
The OIDs beginning with "1.3.6.1.4.1.890.1.5.8.68" are specific to the MES3500-24 switch.
The OIDs beginning with "1.3.6.1.4.1.890.1.5.8.57" are specific to the MES3500-24F switch.
Table 120 SNMP System Traps
OPTION
OBJECT LABEL
coldstart
coldStart
warmstart
warmStart
temperature
TemperatureEventOn
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
292
OBJECT ID
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
DESCRIPTION
This trap is sent when the Switch is turned
on.
This trap is sent when the Switch restarts.
This trap is sent when the temperature goes
above or below the normal operating range.
This trap is sent when the temperature
returns to the normal operating range.
This trap is sent when the voltage goes
above or below the normal operating range.
This trap is sent when the voltage returns to
the normal operating range.