ZyXEL Communications MES3500-24F User Manual page 293

Layer 2 management switch
Table of Contents

Advertisement

Table 120 SNMP System Traps (continued)
OPTION
OBJECT LABEL
reset
UncontrolledResetEventO
n
ControlledResetEventOn
RebootEvent
timesync
RTCNotUpdatedEventOn
RTCNotUpdatedEventClea
r
intrusionlock
IntrusionLockEventOn
loopguard
LoopguardEventOn
errdisable
errdisableDetectTrap
errdisableRecoveryTrap
externalalar
ExternalAlarmEventOn
m
ExternalAlarmEventClear
dyinggasp
DyingGaspEventOn
Table 121 SNMP Interface Traps
OPTION
OBJECT LABEL
linkup
linkUp
LinkDownEventClear
linkdown
linkDown
LinkDownEventOn
MES3500-24/24F User's Guide
OBJECT ID
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.0.1
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.4.1.890.1.5.8.68.130.4.1
1.3.6.1.4.1.890.1.5.8.57.130.4.1
1.3.6.1.4.1.890.1.5.8.68.130.4.2
1.3.6.1.4.1.890.1.5.8.57.130.4.2
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
OBJECT ID
1.3.6.1.6.3.1.1.5.4
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.6.3.1.1.5.3
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
Chapter 38 Access Control
DESCRIPTION
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets by
an administrator through a management
interface.
This trap is sent when the Switch reboots by
an administrator through a management
interface.
This trap is sent when the Switch fails to get
the time and date from a time server.
This trap is sent when the Switch gets the
time and date from a time server.
This trap is sent when intrusion lock occurs
on a port.
This trap is sent when loopguard shuts down
a port.
This trap is sent when an error is detected
on a port, such as a loop occurs or the rate
limit for specific control packets is
exceeded.
This trap is sent when the Switch ceases the
action taken on a port, such as shutting
down the port or discarding packets on the
port, after the specified recovery interval.
This trap is sent when the external alarm is
received.
This trap is sent when the external alarm
stops sending an alert.
The trap is sent when the device power goes
below the normal value.
DESCRIPTION
This trap is sent when the Ethernet link is
up.
This trap is sent when the Ethernet link is
up.
This trap is sent when the Ethernet link is
down.
This trap is sent when the Ethernet link is
down.