configured for in-band connectivity. To take effect, 'MAC Address Type' must be set to 'Locally
Administered'. Enter the address as twelve hexadecimal digits (6 bytes) with a colon between each
byte. Bit 1 of byte 0 must be set to a 1 and bit 0 to a 0, i.e. byte 0 should have the following mask
'xxxx xx10'. The MAC address used by this bridge when it must be referred to in a unique fashion.
It is recommended that this be the numerically smallest MAC address of all ports that belong to this
bridge. However it is only required to be unique. When concatenated with dot1dStpPriority a
unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol.
MAC Address Type - Specifies which MAC address should be used for in-band connectivity. The
choices are the burned in or the Locally Administered address. The factory default is to use the
burned in MAC address.
Network Configuration Protocol Current - Indicates which network protocol is being used. The
options are bootp | dhcp | none.
Java Mode - Specifies if the switch should allow access to the Java applet in the header frame.
Enabled means the applet can be viewed. The factory default is disabled.
Management VLAN ID - Specifies the management VLAN ID.

8.5.15 show remotecon

This command displays telnet settings.
Format
show remotecon
Mode
Privileged EXEC and User EXEC
Remote Connection Login Timeout (minutes) - This object indicates the number of minutes a remote
connection session is allowed to remain inactive before being logged off. A zero means there will be no
timeout. This may be specified as a number from 0 to 160. The factory default is 5.
Maximum Number of Remote Connection Sessions - This object indicates the number of
simultaneous remote connection sessions allowed. The factory default is 5.
Allow New Telnet Sessions - Indicates that new telnet sessions will not be allowed when set to no. The
factory default value is yes.

8.5.16 show serial

This command displays serial communication settings for the switch.
Format
show serial
Mode
Privileged EXEC and User EXEC
Serial Port Login Timeout (minutes) - Specifies the time, in minutes, of inactivity on a Serial port
connection, after which the Switch will close the connection. Any numeric value between 0 and 160 is
allowed, the factory default is 5. A value of 0 disables the timeout.
Baud Rate - The default baud rate at which the serial port will try to connect. The available values are
1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 baud. The factory Default is 9600 baud.
Character Size - The number of bits in a character. The number of bits is always 8.