requested be transmitted to the Broadcast address, including those that were discarded or not
sent.
Transmit Errors
Total Errors - The sum of Single, Multiple, and Excessive Collisions.
Tx FCS Errors - The total number of packets transmitted that had a length (excluding framing bits,
but including FCS octets) of between 64 and 1518 octets, inclusive, but had a bad Frame Check
Sequence (FCS) with an integral number of octets
Oversized - The total number of frames that exceeded the max permitted frame size. This counter
has a max increment rate of 815 counts per sec. at 10 Mb/s.
Underrun Errors - The total number of frames discarded because the transmit FIFO buffer
became empty during frame transmission.
Transmit Discards
Total Discards - The sum of single collision frames discarded, multiple collision frames discarded,
and excessive frames discarded.
Single Collision Frames - A count of the number of successfully transmitted frames on a
particular interface for which transmission is inhibited by exactly one collision.
Multiple Collision Frames - A count of the number of successfully transmitted frames on a
particular interface for which transmission is inhibited by more than one collision.
Excessive Collisions - A count of frames for which transmission on a particular interface fails due
to excessive collisions.
Port Membership - The number of frames discarded on egress for this port due to egress filtering
being enabled.
VLAN Viable Discards - The number of frames discarded on this port when a lookup on a
particular VLAN occurs while that entry in the VLAN table is being modified, or if the VLAN has not
been configured.
Protocol Statistics
BPDU's received - The count of BPDU's (Bridge Protocol Data Units) received in the spanning
tree layer.
BPDU's Transmitted - The count of BPDU's (Bridge Protocol Data Units) transmitted from the
spanning tree layer.
802.3x Pause Frames Received - A count of MAC Control frames received on this interface with
an opcode indicating the PAUSE operation. This counter does not increment when the interface is
operating in half-duplex mode.
GVRP PDU's Received - The count of GVRP PDU's received in the GARP layer.
GVRP PDU's Transmitted - The count of GVRP PDU's transmitted from the GARP layer.
GVRP Failed Registrations - The number of times attempted GVRP registrations could not be
completed.
GMRP PDU's received - The count of GMRP PDU's received in the GARP layer.