Mb-106 Carrying Handle; Band Voltage Modification - Icom IC-7000 Instruction Manual

Hf/vhf/uhf all mode transceiver
Hide thumbs Also See for IC-7000:
Table of Contents

Advertisement

■ MB-106
carrying handle
The optional MB-106
carrying handle
when carrying the transceiver for DX' peditions, field
operation, etc.
q Attach the rubber feet with the supplied screws as
shown below.
Rubber
feet

■ Band voltage modification

If you want to connect an external unit which can be
controlled by the band voltage from [ACC] connec-
tor, the following modification is necessary. The band
voltage appears on pin 5 of [ACC] connector after
modification is completed.
Performing this modification is the customer's re-
sponsibility. Icom does not guarantee this modifi-
cation's result.
CAUTION:
Disconnect the DC power cable
from the transceiver before any work on the
transceiver.
• Band voltage generator circuit
The below circuit is just for reference.
ACC socket of
GND
an optional unit
6
7
8 V
3
1
4700 pF
5
4
2
Diode
BAND
100 µH
4700 pF
4700 pF
4.7 kΩ
OPTION UNITS SETTING
is convenient
Extenal
power souce
8 V
100 µH
Rotary
switch
1.9 MHz
3.5 MHz
VR
4.7 kΩ
7 MHz
4.7 kΩ
VR
10 MHz
Open
10 kΩ
14 MHz
VR
18/21 MHz
10 kΩ
VR
24/28 MHz
22 kΩ
OR
w Attach the MB-106 to the left side of the trans-
ceiver as shown below.
Carrying
handle
IC-7000's top view with
DDS unit
top panel is opened
Cooling
fan
Front panel
Bridge these
solder pads
The following band voltage table is for reference
only. Please adjust and confirm against the actual
operating condition.
BAND
1.9 MHz
3.5 MHz
7 MHz
10 MHz
14 MHz
18/21 MHz
24/28 MHz
16
VOLTAGE
6.1 V
5.1 V
4.1 V
3.1 V
2.1 V
15
16
140