Carrying Handle; Dsp Receiver Unit - Icom IC-703 Instruction Manual

Hf/50 mhz all mode transceiver
Hide thumbs Also See for IC-703:
Table of Contents

Advertisement

I UT-106

DSP RECEIVER UNIT

q Open the transceiver top cover as shown on p. 86.
w Remove the 4-pin connector (P2451) from main
CPU shielding case on the MAIN unit (top side)
and plug it into J1 of the UT-106.
J2451
MAIN unit
P2451
(top side)
e Plug the 4-pin connector (P1) from the UT-106 into
J2451 on the MAIN unit.
r Plug the supplied flat cable into J3 on the UT-106
and J2453 on the MAIN unit.
• Be careful of the orientation of the flat cable.
t Attach the UT-106 to the main CPU shielding case,
using the existing guide for alignment, as illustrated
at right above
I MB-72

CARRYING HANDLE

The optional MB-72
CARRYING HANDLE
when carrying the transceiver for DX'peditions, field
operation, etc.
q Tighten the supplied screws plus rubber feet as
shown below.
Rubber
feet
OPTION UNIT INSTALLATIONS AND SETTINGS
(UT-106)
Front side
Main CPU
shielding case
y Reassemble the transceiver.
is convenient
w Attach the MB-72 to the left side of the transceiver
as shown below.
P1
UT-106
J2451
J3
Flat cable
J2453
Carrying handle
15
Front side
J1
P2451
15
88

Advertisement

Table of Contents
loading

Table of Contents