OPTIONAL INSTALLATIONS/SETTINGS
I UT-106

DSP RECEIVER UNIT

D Installation
Open the transceiver case as shown on p. 59.
Remove the 4-pin connector (P251) from J1413 on
the MAIN unit (top side) and plug it into J1 of the
UT-106 on the PLL unit (bottom side).
Plug the 4-pin connector (P1) from the UT-106 into
J1413 on the MAIN unit.
Plug the supplied ribbon cable into J3 on the UT-
106 and J253 on the PLL unit.
• Be careful of the orientation of the ribbon cable.
Attach the UT-106 to the PLL unit, using the exist-
ing guide for alignment, as illustrated at right.
Reassemble the transceiver.
DOperation
Refer to the instructions supplied with the UT-106 for
operating details.
I MB-72

CARRYING HANDLE

The optional MB-72
when carrying the transceiver for DX'peditions, field
operation, etc.
Remove the 2 screws from the right side of the
transceiver as shown below.
Replace those with 2 supplied screws plus rubber
rubber
feet
61
is convenient
CARRYING HANDLE
MAIN unit
Remove the J1431 connector
P1
from the PLL unit and replace
J1431
with the UT-106 connector
Be careful of the orientation
when connecting the
UT-106
ribbon cable.
J3
J1
J1
P251
P253
P1
unit position
feet and additionally attach 2 more supplied
screws (including rubber feet) as shown below.
• When replacing the 2 screws at the rear, be sure to
squeeze the top and bottom covers together to ensure
proper alignment.
Attach the MB-72 to the left side of the transceiver
as shown below.
carrying
handle
PLL unit