9 MAJOR POSITIONING CONTROL

9.2.19 Current value changing

When the current value is changed to a new value, control is carried out in which the
Md.20
"
Current feed value" of the stopped axis is changed to a random address set
by the user. (The "
Md.21
is changed.)
The two methods for changing the current value are shown below.
[1] Changing to a new current value using the positioning data
[2] Changing to a new current value using the start No. (No. 9003) for a current
value changing
The current value changing using method [1] is used during continuous positioning of
multiple blocks, etc.
[1] Changing to a new current value using the positioning data
Operation chart
The following chart shows the operation timing for a current value changing. The
Md.20
"
Current feed value" is changed to the value set in "
address/movement amount" when the positioning start signal turns ON.
Positioning start signal
[Y10,Y11,Y12,Y13]
Md.20
Current feed value
Restrictions
(1) An axis error "New current value not possible (error code: 515)" will occur and
the operation cannot start if "continuous path control" is set in "
Operation pattern". ("Continuous path control" cannot be set in current value
changing.)
(2) "Current value changing" cannot be set in "
positioning data when "continuous path control" has been set in "
Operation pattern" of the immediately prior positioning data. (For example, if
the operation pattern of positioning data No. 1 is "continuous path control",
"current value changing" cannot be set in positioning data No. 2.) An axis error
"New current value not possible (error code: 515)" will occur and the machine
will carry out a deceleration stop if this type of setting is carried out.
(3) An axis error "Outside new current value range (error code: 514)" will occur
and the operation cannot start if "degree" is set in "
Da.6
value set in "
setting range (0 to 359.99999 [degree]).
Machine feed value" is not changed when the current value
ON
OFF
50000
0
Positioning address/movement amount" is outside the
9 - 105
MELSEC-Q
Da.6
Current feed value changes to the
positioning address designated by the
positioning data of the current value changing.
The above chart shows an example
when the positioning address is "0".
Da.2
Control system" of the
Pr.1
Unit setting" and the
Positioning
Da.1
Da.1

Advertisement

loading

This manual is also suitable for:

Melsec-q qd75p2Melsec-q qd75p4Melsec-q qd75d1Melsec-q qd75d4Melsec-q qd75d2Qd75p1 ... Show all