Download Print this page

Mitsubishi Melsec-Q QD75P1 User Manual page 349

Programmable logic controller q-series
Hide thumbs Also See for Melsec-Q QD75P1:

Advertisement

9 MAJOR POSITIONING CONTROL
Restrictions
(1) An axis error "Continuous path control not possible (error code: 516)" will
occur and the operation cannot start if "continuous path control" is set in
Da.1
"
Operation pattern". ("Continuous path control" cannot be set in fixed-
feed control.)
(2) If the movement amount of each axis exceeds "1073741824 (=2
Composite speed" is set in " Pr.20 Interpolation speed designation method",
the "Outside linear movement amount range error (error code: 504)" occurs at
a positioning start and positioning cannot be started. (The maximum
movement amount that can be set in "
amount" is "1073741824 (= 2
(3) "Fixed-feed" cannot be set in "
when "continuous path control" has been set in "
the immediately prior positioning data. (For example, if the operation pattern of
positioning data No. 1 is "continuous path control", fixed-feed control cannot
be set in positioning data No. 2.) An axis error "Continuous path control not
possible (error code: 516)" will occur and the machine will carry out a
deceleration stop if this type of setting is carried out.
Positioning data setting example
[Reference axis is designated as axis 1.]
The following table shows setting examples when "3-axis fixed-feed control (fixed-
feed 3)" is set in positioning data No. 1 of axis 1. (The required values are also set
in positioning data No. 1 of axis 2 and axis 3.)
Da.6
30
)".
Da.2
Control system" in the positioning data
9 - 49
MELSEC-Q
30
)" when "0:
Positioning address/movement
Da.1
Operation pattern" of

Advertisement

loading

This manual is also suitable for:

Melsec-q qd75p2Melsec-q qd75p4Melsec-q qd75d1Melsec-q qd75d4Melsec-q qd75d2Qd75p1 ... Show all