9 MAJOR POSITIONING CONTROL

9.2.12 1-axis speed control

Da. 8 Command speed
Positioning start signal
BUSY signal
Positioning complete signal
Axis stop signal
(stop command) [Y4]
In speed control flag
Md.31 Status:b0
In "1-axis speed control" ("
run: speed 1), control is carried out in the axis direction in which the positioning data
has been set by continuously outputting pulses for the speed set in "
speed" until the input of a stop command.
The two types of 1-axis speed control are "Forward run: speed 1" in which the control
starts in the forward run direction, and "Reverse run: speed 1" in which control starts in
the reverse run direction.
Operation chart
The following chart shows the operation timing for 1-axis speed control with axis 1
as the reference axis.
The "in speed control" flag (
The "Positioning complete signal" is not turned ON.
V
ON
OFF
[Y10]
OFF
[XC]
OFF
[X14]
OFF
OFF
Fig.9.9 1-axis speed control operation timing
Da.2
Control system" = Forward run: speed 1, Reverse
Md.31
Status: b0) is turned ON during speed control.
ON
ON
9 - 67
t
Does not turn ON even
when control is stopped
by stop command.
ON
MELSEC-Q
Da.8
Command

Advertisement

loading

This manual is also suitable for: