Download Print this page

Install Operation (Installing Additional Shared Memory) - HP StorageWorks XP20000/XP24000 - Disk Array Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96071, december 2009)
Hide thumbs Also See for StorageWorks XP20000/XP24000 - Disk Array:

Advertisement

Detailed information displays for this operation, as shown in
Table 125 Install Operation (Installing Additional Shared Memory)
Item
Description
SM
The mounting location of the PCB for shared memory.
Slot
The slot position of the shared memory module.
Size
The capacity of the cache memory module.
Num of SMMs
The number of shared memory modules.
PP Flag
The option flags.
Num of PP Flags
The number of option flags.
Max Number of
The maximum number of CUs.
CUs
Battery
The mounting location of the battery
Indicates the installation or the uninstallation of the battery.
Define
Install: Install battery, Uninstall: Uninstall battery.
Num. of Batteries
The number of batteries.
NOTE:
Only the changed items will be output.
Example 5 (installing additional power supply)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Install,,Normal end,,,Seq.=xxxxx
+Redundant Power Supply=[CL Additional Power Supply,CL Additional Power Supply2],
Num. of Redundant Power Supplies=2
[Install]
Install function
Install
Install operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
166
Install Function
Table
125.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Storageworks xp24000Storageworks xp20000