15 Data Retention Utility Function
Attribute Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Data Ret],Attribute,,Normal end,,,Seq.=xxxxx
+{LDKC:CU:LDEV,Attribute,RT,Result}=[{0x00:0x00:0x01,0x80,100,Normal end},
{0x00:0x00:0x02,0x82,Unlimited,Error(9605-8122)},{0x00:0x00:0x03,0x81,200,
Normal end},
{0x00:0x00:0x03,0x81,xxxx,Normal end}],Num. of LDEVs=XXX
[Data Ret]
Data Retention Utility function
Attribute
Attribute operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 72 Attribute Operation
Item
LDKC:CU:LDEV
Attribute
Description
The LDKC, CU, and LDEV numbers of the logical volume where the attribute is set.
The set attribute in hexadecimal. Each bit (0-7) of 1 byte corresponds to the setting item.
1 is assigned to each bit when the setting is enabled and 0 (zero) is assigned to each
bit when the setting is disabled. Each bit represents the following attributes:
Bit 0: Mounting of LDEV (fixed to 1)
Bit 1: Setting of S-VOL Disable
Bit 2: Setting of Zero Read Cap mode
Bit 3: Setting of Invisible mode
Bit 4: Setting of reserve
1
Bit 5: Fixed to 0 (zero)
Bit 6: Setting of Read Only attribute
Bit 7: Setting of Protect attribute
When 0x88 is output to the attribute, for example, Read/Write attribute is set to the
logical volume to show that the reserve setting has been enabled.
A hyphen (-) is output when setting is not changed.
XP24000/XP20000 Audit Log User and Reference Guide
Table
72.
1
1
117