Item
Result
Num. of EXCTGs

Journal-Option Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[UR],Journal-Option,,Normal end,Seq.=xxxxx
+{LDKC,JNLG,MetaData Ratio,Extent,Data Overflow Watch(s),Inflow Control,Copy Pace,
Timer Type,
Path Watch Time,Forward Path Watch Time,Use of Cache,Speed of Line(Mbps),Delta
resync Failure,Result}=
-{0x00,0x00,32,32,20,No,150,Local,30(min.),Yes,Not Use,256,Entire,Normal end},
(snip),
{0x00,0x02,32,32,20,No,150,Local,30(min.),Yes,Not Use,256,Entire,Normal end},
Num. of JNL Grps=3
[UR]
Universal Replicator for Mainframe function (for IBM z/OS)
Journal-Option

Journal-Option operation

Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 269 Journal-Option Operation
Item
LDKC
JNLG
MetaData Ratio
Extent
Data Overflow
Watch(s)
Inflow Control
Description
The result of the operation
Normal end: normal end, Error(xxxx-yyyyy): abnormal end
xxxx: part code, yyyyy: error code
The number of extended consistency groups for which the configuration has been
changed
Description
The journal group's LDKC number.
The journal group number.
The ratio of the metadata to the journal data.
When the ratio is 1:32, the number for MetaData Ratio is 32.
The number of extents.
The overflow watch time of the metadata or journal data. The unit is second.
Indicates whether or not inflow control is executed. Yes: Controlled, No: Not controlled
XP24000/XP20000 Audit Log User and Reference Guide
Table
269.
297