Monitoring Enclosures; Monitoring Battery Backup Units - LSI X79 Extreme11 User Manual

Lsi mega raid storage manager guide
Hide thumbs Also See for X79 Extreme11:
Table of Contents

Advertisement

Note:
If the drives in the virtual drive are in a disk enclosure, you can identify them by making their LEDs
blink. To identify the drives, follow these steps:
1. Click the virtual drive icon in the left panel.
2. Either select Go To->Virtual Drive->Start Locating Virtual Drive, or right-click a virtual drive
and select Start Locating Virtual Drive from the menu.
The LEDs on the drives in the virtual drive start blinking (except for the hot spare drives).
3. To stop the LEDs from blinking, select Go To->Virtual Drive->Stop Locating Virtual Drive
or right-click a virtual drive and select Stop Locating Virtual Drive from the menu.

Monitoring Enclosures

When the MegaRAID Storage Manager software is running, you can see the status of all
enclosures connected to the server by selecting the Physical tab in the left panel. If an enclosure
is operating normally, the icon looks like this:
example, if a fan has failed—an orange, yellow, or red circle appears to the right of the icon.
Information about the enclosure appears in the right panel when you select the Properties tab on
the main menu screen. A graphical display of enclosure information appears when you select the
Graphical View tab.
The display in the center of the screen shows how many slots of the enclosure are actually
populated by the drives and the lights on the drives show the drive status. The information on the
right shows you the status of the temperature sensors, fans, and power supplies in the enclosure.
To view the enclosure properties, in the physical view click on the Enclosure node. The
Enclosure Properties are displayed, as shown in the following figure.
Figure 65

Monitoring Battery Backup Units

When the MegaRAID Storage Manager software is running, you can monitor the status of all of
the BBUs connected to controllers in the server. If a BBU is operating normally, the icon looks like
this
Page 84
Monitoring Controllers and Its Attached Devices
DB09-000202-05 37857-02
Rev. F - May 2011
You can change the Read Policy, Write Policy, and other virtual drive properties by
selecting the virtual drive icon and then selecting Go To->Virtual Drive ->Set Virtual
Drive Properties in the menu bar.
Enclosure Properties
. If a BBU fails, a red dot appears next to the icon.
Copyright © 2011 by LSI Corporation. All rights reserved.
. If an enclosure is not functioning normally—for