Optimum Controller Settings for CacheCade - SSD Caching
•
Write Policy: Write Back
•
IO Policy: Cached IO
•
Read Policy: No Read Ahead
•
Stripe Size: 64 KB
Optimum Controller Settings for FastPath
•
Write Policy: Write Through
•
IO Policy: Direct IO
•
Read Policy: No Read Ahead
•
Stripe Size: 64 KB
Creating a Virtual Drive Using Simple Configuration
Simple configuration mode is the quickest and easiest way to create a new storage configuration.
When you select simple configuration mode, the system creates the best configuration possible
using the available drives.
Note:
Follow these steps to create a new storage configuration in a simple configuration mode.
1. Access the Create Virtual Drive dialog by performing either of the following steps:
•
Right-click the controller node in the device tree in the left frame of the MegaRAID Storage
Manager main menu screen, and select Create Virtual Drive.
•
Select the controller node, and select Operations->Create Virtual Drive in the menu bar, as
shown in the following figure.
Figure 21
Configuration
DB09-000202-05 37857-02
Rev. F - May 2011
You cannot create spanned drives using the simple configuration procedure. To
create spanned drives, use the advanced configuration procedure described in
Creating a Virtual Drive Using Advanced
Virtual Drive Creation Menu
Copyright © 2011 by LSI Corporation. All rights reserved.
Configuration.
Page 39