Optimum Controller Settings for CacheCade - SSD Caching
Write Policy: Write Back
IO Policy: Cached IO
Read Policy: No Read Ahead
Stripe Size: 64 KB

Optimum Controller Settings for FastPath

Write Policy: Write Through
IO Policy: Direct IO
Read Policy: No Read Ahead
Stripe Size: 64 KB

Creating a Virtual Drive Using Simple Configuration

Simple configuration mode is the quickest and easiest way to create a new storage configuration.
When you select simple configuration mode, the system creates the best configuration possible
using the available drives.
Note:
Follow these steps to create a new storage configuration in a simple configuration mode.
1. Access the Create Virtual Drive dialog by performing either of the following steps:
Right-click the controller node in the device tree in the left frame of the MegaRAID Storage
Manager main menu screen, and select Create Virtual Drive.
Select the controller node, and select Operations->Create Virtual Drive in the menu bar, as
shown in the following figure.
Figure 21
Configuration
DB09-000202-05 37857-02
Rev. F - May 2011
You cannot create spanned drives using the simple configuration procedure. To
create spanned drives, use the advanced configuration procedure described in
Creating a Virtual Drive Using Advanced
Virtual Drive Creation Menu
Copyright © 2011 by LSI Corporation. All rights reserved.
Configuration.