LSI X79 Extreme11 User Manual page 63

Lsi mega raid storage manager guide
Hide thumbs Also See for X79 Extreme11:
Table of Contents

Advertisement

3. Either select Go To->Drive Group->Modify Drive Group on the menu bar, or right-click the
virtual drive icon to access the Modify Drive Group Wizard.
The Modify Drive Group Wizard appears, as shown in the following figure.
Figure 49
4. On the Modify Drive Group Wizard screen, select the RAID level that you want to change
(migrate) the drive group to, and click Next.
The following screen appears. The screen states the number of drives that you have to add
to change the RAID level from the current level to a new RAID level that requires more drives.
Figure 50
5. Select the check box next to the unconfigured drive or drives to add, and click Next.
Note:
Configuration
DB09-000202-05 37857-02
Rev. F - May 2011
Modify Drive Group Wizard
Add Drive(s) to the Current Configuration Screen
The drive or drives you add must have the same capacity as or greater capacity than
the drives already in the drive group, or you cannot change the RAID level.
Copyright © 2011 by LSI Corporation. All rights reserved.
Page 63