Enabling Rmon Alarms For Vsans; Enabling Rmon Alarms For Physical Components - Cisco DS-C9216I-K9 Configuration Manual

Switch guide
Table of Contents

Advertisement

Chapter 28
Configuring System Message Logging
Check the check box for each variable that you want to monitor.
Step 5
Enter the threshold value in the Value column.
Step 6
Enter the sampling period in seconds.
Step 7
Choose one of the following severity levels to assign to the alarm:
Step 8
Click Create.
Step 9
Confirm the operation to define an alarm and a log event when the system prompts you to define a
Step 10
severity event.
If you do not confirm the operation, the system only defines a log event.

Enabling RMON Alarms for VSANs

To manage RMON alarm service attributes for selected VSANs from the Device Manager, choose
Events > Threshold Manager and click the Services tab. You see the Threshold Manager dialog box
with the Services tab selected.
To enable an RMON alarm for one or more VSANs, follow these steps:
Enter one or more VSANs to monitor in the VSAN Id(s) field.
Step 1
Check the check box for each variable that you want to monitor.
Step 2
Enter the threshold value in the Value column.
Step 3
Enter the sampling period in seconds.
Step 4
Select a severity level to assign to the alarm:
Step 5
Click Create.
Step 6
Step 7
Confirm the operation to define an alarm and a log event when the system prompts you to define a
severity event.
If you do not confirm the operation, the system only defines a log event.

Enabling RMON Alarms for Physical Components

To configure RMON alarm physical attributes from the Device Manager, choose Events > Threshold
Manager and click the Physical tab. You see the Create RMON Alarms dialog box with the Physical tab
selected.
To configure an RMON alarm for a physical component, follow these steps:
OL-7753-01
Fatal
Warning
Critical
Error
Information
Cisco MDS 9000 Fabric Manager Switch Configuration Guide
About RMON Facilities
28-9