Configuring Ipfc; Configuring Overlay Vsans - Cisco DS-C9216I-K9 Configuration Manual

Switch guide
Table of Contents

Advertisement

Configuring IPFC

The following is an example of an input ACL log dump.
Jul 17 20:38:44 excal-2%KERN-7-SYSTEM_MSG:%IPACL-7-DENY:IN=vsan1 OUT=
MAC=10:00:00:05:30:00:47:df:10:00:00:05:30:00:8a:1f:aa:aa:03:00:00:00:08:00:45:00:00:54:00
:00:40:00:40:01:0e:86:0b:0b:0b:0c:0b:0b:0b:02:08:00:ff:9c:01:15:05:00:6f:09:17:3f:80:02:01
:00:08:09:0a:0b:0c:0d:0e:0f:10:11:12:13:14:15:16:17:18:19:1a:1b:1c:1d:1e:1f:20:21:22:23:24
:25:26:27:28:29:2a:2b SRC=11.11.11.12 DST=11.11.11.2 LEN=84 TOS=0x00 PREC=0x00 TTL=64 ID=0
DF PROTO=ICMP TYPE=8 CODE=0 ID=277 SEQ=1280
The following is an example of an output ACL log dump.
Jul 17 20:38:44 excal-2%KERN-7-SYSTEM_MSG:%IPACL-7-DENY:IN= OUT=vsan1 SRC=11.11.11.2
DST=11.11.11.12 LEN=84 TOS=0x00 PREC=0x00 TTL=255 ID=38095 PROTO=ICMP TYPE=0 CODE=0 ID=277
SEQ=1280
Configuring IPFC
Once the VSAN interface is created, you can specify the IP address for that VSAN.

Configuring Overlay VSANs

VSANs enable deployment of larger SANs by overlaying multiple logical SANs, each running its own
instance of fabric services, on a single large physical network. This partitioning of fabric services
reduces network instability by containing fabric reconfiguration and error conditions within an
individual VSAN. VSANs also provide the same isolation between individual VSANs as physically
separated SANs. Traffic cannot cross VSAN boundaries and devices may not reside in more than one
VSAN. Because each VSAN runs separate instances of fabric services, each VSAN has its own zone
server and can be zoned in exactly the same way as SANs without VSAN capability.
To configure an overlay VSAN, follow these steps:
To configure the management interface displayed in
on the Ethernet network.
Add the VSAN to the VSAN database on all switch in the fabric.
Step 1
Create a VSAN interface for the VSAN on all switches in the fabric. Any VSAN interface belonging to
Step 2
the VSAN has an IP address in the same subnet. Create a route to the IPFC cloud on the IP side
Configure a default route on every switch in the Fibre Channel fabric pointing to the switch that provides
Step 3
NMS access.
Configure default gateway (route) and the IP address on switches that point to the NMS.
Step 4
Cisco MDS 9000 Fabric Manager Switch Configuration Guide
22-8
Chapter 22
Figure
22-4, set the default gateway to an IP address
Configuring IP Services
OL-7753-01

Advertisement

Table of Contents
loading

Table of Contents