Cisco DS-C9216I-K9 Configuration Manual page 118

Switch guide
Table of Contents

Advertisement

Identifying Module LEDs
Table 9-4
LED
Status
System
Active
Pwr Mgmt1
Table 9-5
Table 9-5
Module
Ethernet (mgmt 0)
Table 9-6
Cisco MDS 9000 Fabric Manager Switch Configuration Guide
9-4
Supervisor Module LEDs on a Cisco MDS 9500 Series Switch
Status
Green
Orange
Red
Green
Orange
Red
Green
Orange
Green
Orange
lists the Ethernet interface LEDs on a Cisco MDS 9200 Series Switch.
Ethernet Interface LEDs on a Cisco MDS 9200 Series Switch
LED Type
Activity
Link
lists the switching module LEDs.
Chapter 9
Description
All diagnostics pass. The module is online.
The module is booting or running diagnostics
(normal initialization sequence).
The module is not online.
An over temperature condition has occurred.
(A minor threshold has been exceeded during
environmental monitoring.)
The diagnostic test failed. The module is not
operational because a fault occurred during
the initialization sequence.
An over temperature condition has occurred.
(A major threshold has been exceeded during
environmental monitoring.)
All chassis environmental monitors (power supply,
fan, temperature sensor, clock, and chassis) are
reporting OK.
Any one of the environmental monitors
(power supply, fan, temperature sensor, clock,
and chassis) has failed.
Incompatible power supplies are installed.
The redundant clock has failed.
The temperature of the supervisor module major
threshold has been exceeded.
The supervisor module is operational and active.
The supervisor module is in standby mode.
Sufficient power is available for all modules.
Sufficient power is not available for all modules.
Status
Flashing green
Solid green
Off
Managing Modules
Description
Traffic is passing
through the interface.
The link is functioning.
The link is down.
OL-7753-01