Cisco DS-C9216I-K9 Configuration Manual page 342

Switch guide
Table of Contents

Advertisement

Event Triggers
Table 25-2
Event
Supervisor
Hardware and
CISCO_TAC
Supervisor
Hardware and
CISCO_TAC
License
Inventory
HARDWARE_IN
SERTION
HARDWARE_RE
MOVAL
Test
Table 25-3
Event Category
System
Environmental
Switching module hardware
Supervisor hardware
Cisco MDS 9000 Fabric Manager Switch Configuration Guide
25-6
Event Triggers (continued)
Alert Group
EOBC_FAILURE
MGMT_PORT_FA
ILURE
LICENSE_VIOLA
TION
Inventory and
CISCO_TAC
New piece of
hardware inserted
into the chassis.
Hardware removed
from the chassis.
Test and
CISCO_TAC
Event Categories and Command Outputs
Description
Events generated by failure of a
software system that is critical to
unit operation.
Events related to power, fan, and
environment sensing elements
such as temperature alarms.
Events related to standard or
intelligent switching modules.
Events related to supervisor
modules.
Event Name
Description
Ethernet Out of
6
Band Channel
communications
failure
Hardware failure
5
of management
Ethernet port.
Feature in use
6
that is not
licensed (Release
1.3.x), and will
be turned off after
grace period
expiration
COLD_BOOT
Switch is powered
up and reset to a
cold boot sequence.
2
2
TEST
User generated test. 2
Chapter 25
Configuring Call Home
Severity Level
2
Executed Commands
show tech-support show
system redundancy status
show module show
environment
show tech-support
show tech-support
OL-7753-01

Advertisement

Table of Contents
loading

Table of Contents