M7i Multiservice Edge Router Hardware Guide
DB-9 Connector Pinouts for the M7i Routing Engine AUX/MODEM and CONSOLE Ports
Table 28: DB-9 Connector Pinout
Pin
1
2
3
4
5
6
7
8
9
Related
Documentation
RJ-48 Cable Pinouts for E1 and T1 PICs
182
Replacing the Routing Engine Interface Port Cables on page 99
DB-9 Connector Pinouts for the M7i Routing Engine AUX/MODEM and CONSOLE Ports
on page 182
The ports on the CIP labeled
accept RS-232 (EIA-232) cable. The
a laptop, modem, or other auxiliary unit, and the
management console. The ports are configured as data terminal equipment (DTE). Table
28 on page 182 describes the DB-9 connector pinouts.
Signal
Direction
DCD
<–
RxD
<–
TxD
–>
DTR
–>
Ground
—
DSR
<–
RTS
–>
CTS
<–
RING
<–
M7i Routing Engine Description on page 18
Maintaining the M7i Routing Engine on page 72
Replacing the M7i Routing Engine on page 97
Replacing the Routing Engine Interface Port Cables on page 99
RJ-45 Connector Pinouts for the M7i Routing Engine MGMT Port on page 181
The E1 and T1 PICs use an RJ-48 cable, which is not supplied with the PIC.
and
AUX/MODEM
CONSOLE
port connects the Routing Engine to
AUX/MODEM
CONSOLE
Description
Carrier Detect
Receive Data
Transmit Data
Data Terminal Ready
Signal Ground
Data Set Ready
Request To Send
Clear To Send
Ring Indicator
Copyright © 2010, Juniper Networks, Inc.
are DB-9 receptacles that
port connects it to a