Dc Power Lugs; Figure 62: Dc Power Cable Connections - Juniper M7I Hardware Manual

Multiservice edge router
Hide thumbs Also See for M7I:
Table of Contents

Advertisement

Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
Appendix D: Power Guidelines, Requirements, and Specifications for the M7i Router
WARNING: For field-wiring connections, use copper conductors only.
For other electrical safety information, see .
NOTE: Power cords and cables must not block access to router components
or drape where people could trip on them.
Figure 62 on page 169 shows how to attach the DC power cables. The power cables insert
into the field-wiring terminals located on each power supply— the input terminal is labeled
and the return terminal is labeled
-48V

Figure 62: DC Power Cable Connections

DC Power Lugs

CAUTION: Before router installation begins, a licensed electrician must attach
a cable lug to the power cables that you supply. A cable with an incorrectly
attached lug can damage the router (for example, by causing a short circuit).
M7i DC Power Supply on page 23
Replacing a DC Power Supply on page 111
Replacing an M7i DC Power Cable on page 115
M7i Router Power Requirements on page 163
M7i Router DC Power Supply Specifications on page 170
.
RTN
169