Minolta DI750 - MANUAL SERVICE Service Manual page 86

Table of Contents

Advertisement

6.
RADF restart timing adjustment
Adjusting the scanner restart timing during RADF
copy.
Caution: Printer restart timing adjustment must
be completed before performing this ad-
justment.
Step
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press "
Image adjustment."
2
3
[Image adjustment mode menu Screen]
Press "
Timing adjustment."
3
4
[Timing adjustment mode menu Screen]
Press "
RADF restart timing adjustment."
6
5
[RADF restart timing adjustment
Screen]
Press the
COPY SCREEN
6
Select A3 (11x17) -size paper, set an ad-
justment chart on RADF, and press the
Start button.
7
Check the leading edge timing on front
and back side.
Specification: within 3 mm
8
If the leading edge timing is not appropri-
ate, press the C button while pressing
the Utility button.
9
[RADF restart timing adjustment
Screen]
Press the
NEXT ADJUSTMENT
PREVIOUS ADJUSTMENT
item to be adjusted.
The screen changes from SIDE1 to
SIDE2.
10
Enter a value with the numeric keys and
press the
SET
Setting range: -60 to +50
1 step=0.1 mm
11
Repeat steps 5 to 10 until the leading
edge timing is within specification.
12
Press the
PREVIOUS SCREEN
turn to the Timing adjustment mode menu
Screen.
Operation
key.
or
key to select the
key.
key to re-
1 - 65
7.
RADF resist loop adjustment
Adjusting the resist loop amount during RADF
copy.
Caution: Printer restart timing adjustment must
be completed before performing this
adjustment.
Step
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press "
Image adjustment."
2
3
[Image adjustment mode menu Screen]
Press "
Timing adjustment."
3
4
[RADF resist loop adjustment Screen]
Press "
RADF restist loop adjustment."
7
5
Press the
COPY SCREEN
switch to Both side - Single side copy
mode.
6
Select A3 (11x17) -size paper, set ad-
justment chart on RADF, and press the
Start button.
7
Check the loop amounts on the front and
back sides.
8
If the registration loop amount is not ap-
propriate, press the C button while press-
ing the Utility button.
9
[RADF resist loop adjustment Screen]
Press the
NEXT ADJUSTMENT
PREVIOUS ADJUSTMENT
item to be adjusted.
The screen changes from SIDE1 to
SIDE2.
10
Enter a value with the numeric keys and
press the
SET
Setting range: -10 to +10
1 step=0.5 mm
11
Repeat steps 5 to 11 until the registra-
tion loop amount is within specification.
12
Press the
PREVIOUS SCREEN
turn to the Timing adjustment mode menu
Screen.
36 ADJUSTMENT
Operation
key and then
or
key to select the
key.
key to re-

Advertisement

Table of Contents
loading

Table of Contents