Minolta DI750 - MANUAL SERVICE Service Manual page 258

Table of Contents

Advertisement

ERROR CODE LIST
Warning
Classification
code
Fan
F32-04
abnormality
F32-05
F32-06
F32-07
ADU stand
F33-01
motor
abnormality
F33-02
F33-03
F33-04
F33-05
Causes
The FM1 EM signal was abnormal 2
seconds after turning ON of FM1
(paper exit). Two seconds after
turning FM1 OFF and ON again, the
FM1 EM signal is still abnormal and
a trouble detection signal (24V off)
is detected.
The FM1 EM signal was abnormal 2
seconds after turning ON of FM1
(paper exit). Two seconds after
turning FM1 OFF and ON again, the
FM1 EM signal is still abnormal and
a trouble detection signal (blown
fuse) is detected.
The FM1 EM signal was abnormal 2
seconds after turning ON of FM1
(paper exit). Two seconds after
turning FM1 OFF and ON again, the
FM1 EM signal is still abnormal and
a trouble detection signal (24V off/
blown fuse) is not detected.
FM1 (paper exit) EM signal becomes
faulty after completion of printing.
A trouble detection signal is detected
2 consecutive times (the first signal
is ignored) 4 seconds after turning
ON of M12 (registration motor).
When M5 (paper reverse/exit) which
has been OFF is turned ON, a trouble
detection signal (blown fuse) is
detected.
When M9 (transfer) which has been
OFF is turned ON, a trouble detection
signal (blown fuse) is detected.
When M10 (paper exit) which has
been OFF is turned ON, a trouble
detection signal (blown fuse) is
detected.
When M16 (Web drive) which has
been OFF is turned ON, a trouble
detection signal (blown fuse/24 V off)
is detected.
4 - 54
Operation in case of
Estimated abnormal
warning occurrence
The machine stops
ADUSDB (ADU
immediately and RL1
stand drive board)
(main) is turned OFF.
FM1 (paper exit)
Error code is not dis-
played on operation
panel. It is displayed
only on data collec-
tion, list output.
The machine stops
M12 (registration)
immediately and RL1
(main) is turned OFF.
If there is a paper in
M5 (paper reverse/
copying
process
exit)
when this jam occurs,
ADUSDB (ADU
the machine stops
stand drive board)
after completion of
M9 (transfer)
copied
paper
ADUSDB (ADU
ejection. RL1 (main)
stand drive board)
is turned OFF.
M10 (paper exit)
ACDB (AC drive
board)
M16 (Web drive)
ACDB (AC drive
board)
parts

Advertisement

Table of Contents