Error Code
01
There is an error in the command to ISW processing unit.
1F
A program error is detected.
41
Input data format error. (during ISW to operation control board)
42
Invalid machine name input data. (during ISW to operation control board)
43
Invalid board name input data. (during ISW to operation control board)
81
Input device error such as input timeout. (during ISW to operation control board)
C1
Failed to erase flash ROM. (during ISW to graphics control board)
C2
Write to flash ROM has failed. (during ISW to graphics control board)
C3
ROM checksum error. (during ISW to graphics control board)
C4
Output device error such as output timeout.
E9
Communication parameter error at image control unit to operation unit I/F.
(during ISW to operation control board)
EA
Command sequence error at image control unit to operation unit I/F.
(during ISW to operation control board)
EB
Communication timeout error at image control unit to operation unit I/F.
(during ISW to operation control board)
F0
Flash ROM error (during ISW to operation control board)
F1
Flash verify error (during ISW to operation control board)
F2
Flash write error (during ISW to operation control board)
F3
Flash erase error (during ISW to operation control board)
F8
Receive checksum error at image control unit to operation unit I/F
(during ISW to operation control board)
F9
Receive header code error at image control unit to operation unit I/F
(during ISW to operation control board)
FA
Receive parity error at image control unit to operation unit I/F
(during ISW to operation control board)
FB
Receive framing error at image control unit to operation unit I/F
(during ISW to operation control board)
FC
Receive overflow error at image control unit to operation unit I/F
(during ISW to operation control board)
<Error code table action classification>
(1) Program is not executing normally.
Restart from power up and re-execute the program.
(2) Check the ISW transfer data file.
(3) Check that the communication cable between input devices (PC) is properly connected.
(4) Check the image control unit to operation unit I/F.
(5) There is an error in the flash ROM on the image control board.
Restart from ISW. If the error persists, the life of the image control board flash ROM may have expired.
Replace the image control board.
(6) An error was detected in the ISW target board. Check the ISW target board.
Description
2 - 9
ISW
Action No.
(1)
(1)
(2)
(2)
(2)
(3)
(5)
(5)
(8)
(6)
(4)
(4)
(4)
(7)
(7)
(7)
(7)
(4)
(4)
(4)
(4)
(4)