Jam
Classification
code
FN-104/
J72-90
FN-4
J73-1
J73-2
J73-3
J73-4
J73-5
J73-6
J73-7
J73-9
J73-10
TMG-1
J73-11
J73-12
J73-13
Cover
J73-14
Inserter A
PK-1
J73-15
Cause
FNS does not stop within the
specific time after it receives start-
operation signal from the main
body.
PS6(paper exit 1) is ON during
idling.
PS5(stacker conveyance passage) is
ON during idling.
PS26(folding passage/2) is ON
during idling.
PS13(entrance paper detection) is
ON during idling.
PS4(FIN entrance passage) is ON
during idling.
PS10(paper exit 2) is ON during
idling.
PS1(subtray paper exit) is ON
during idling.
PS28(folding passage/1) is ON
during idling.
PS25(folding paper exit) is ON
during idling.
PS101(entrance) is ON during
idling.
PS102(conveyance) is ON during
idling.
PS108(exit) is ON during idling.
PS201(sheet passage) is ON
during idling.
The following sensors is ON during
iding.
- Leading/trailing PS on paper edge PS
- PS1(passage)
- PS8(exit)
4 - 41
Machine response
Countermeasure
FNS/main body stops
Remove jammed
immediately.
paper from FNS/main
body if present.
PU/main body stops
Remove jammed
immediately.
paper from PU/main
body.
JAM CODE LIST