ERROR CODE LIST
Warning
Classification
code
EDH-2
E60-01
abnormality
E60-02
E60-03
F60-11
F67-01
F67-02
F67-03
F67-04
F67-05
F67-06
F67-07
F67-08
Causes
A resend request was received after
the main unit had sent data in
response to the data resend request
from EDH-2.
A checksum error or SRGA reception
error was detected when data was
received in response to the data
resend request which had been sent
at detection of a checksum error or
SRGA reception error (dur ing
reception in the serial communication
mode).
No response to initial communication
request from main body to RADF for
5 seconds after SW1 (main switch)
is turned ON.
When SW1 (main switch) was turned
ON, an area which had not been
written by ISW was detected in the
RADF control program.
PS306
(original
registration
detection) fault.
PS308
(original
conveyance
detection) fault.
PS309 (original reversal detection)
fault.
Non-volatile memory fault.
FM301 (ADF fan) fault.
PS304 (reverse jam detection) fault.
PS313 (or iginal exit reverse
detection) fault.
M303 (tray up/dpwn drive) fault.
4 - 66
Operation in case of
Estimated abnormal
warning occurrence
If copy operation is
ICB (image control
being performed, the
board)
main body stops after
DFCB (RADF
paper ejection.
control board)
The RL1 (main) is
C o m m u n i c a t i o n
turned OFF.
cable
DFCB (RADF
control board)
RADF program
If there is a paper in
PS306 (original
copying
process
registration
when this jam occurs,
detection)
the machine stops
PS308 (original
after completion of
conveyance
copied paper ejec-
detection)
tion. RL1 (main) is
PS309 (original
turned OFF.
reversal detection)
DFCB (RADF
control board)
FM301 (ADF fan)
PS304 (reverse
jam detection)
PS313 (original
exit reverse
detection)
M303 (tray up/down
drive)
parts