Jam
Classification
code
EDH-2
J61-1
J61-2
J62-1
J62-2
J62-3
J62-4
J62-5
J62-6
J62-7
Cause
PS301 (RADF open/close
detection) is turned OFF during
RADF operation.
MS301 (cover open/close) is
tur ned OFF during RADF
operation.
PS306 (original registration
detection) remains OFF within the
specified time after start of
prefeed.
PS308 (original conveyance
detection) is not turned ON within
the specified time after start of
prefeed at the front surface of the
two-sided original (including one-
sided original).
PS308 (original conveyance
detection) is not turned ON within
the specified time after start of
prefeed at the back surface of the
two-sided original.
PS308 (original conveyance
detection) is not turned OFF
within the specified time when
M301 (original conveyance roller
drive) is rotating in the forward
direction.
PS308 (original conveyance
detection) is not turned OFF
within the specified time when
M301 (original conveyance roller
drive) is rotating in the backward
direction.
When a large-size two-sided
original is fed into the reversal
section, PS309 (original reversal
detection) is not turned ON within
the specified time after turning
ON of PS308 (original convey-
ance detection).
When a large-size one-sided
original is ejected, PS307
(original exit 1) is not turned ON
within the specified time after
turning ON of PS308 (original
conveyance detection).
4 - 35
Countermeasure
Machine response
RADF stops immedi-
Open the jam
ately.
access cover and
If there is a paper in
remove jammed
or after the copying
paper.
process, the machine
stops after completion
of copied paper
ejection.
JAM CODE LIST