JAM CODE LIST
Jam
Classification
code
J62-8
EDH-2
J62-9
J62-10
J63-1
J63-2
J63-3
J63-4
J63-5
Cause
When a large-size two-sided
or iginal is ejected, PS307
(original exit 1) is not turned ON
within the specified time after
turning ON of PS309 (original
reversal detection).
When a large-size one-sided
original is ejected, PS307
(original exit 1) is not turned OFF
within the specified time.
When a large-size two-sided
original is ejected, PS307
(original exit 1) is not turned OFF
within the specified time.
When a large-size two-sided
original is fed out of the reversal
section, PS309 (original reversal
detection) is not turned ON.
When a large-size two-sided
original is fed into the reversal
section, PS309 (original reversal
detection) is not turned OFF
within the specified time.
When a large-size two-sided
original is fed out of the reversal
section, PS309 (original reversal
detection) is not tur ned OFF
within the specified time.
When a small-size one-sided
or iginal is ejected, PS314
(original exit 2) is not turned ON
within the specified time after
turning ON of PS309 (original
reversal detection).
When a small-size two-sided
original is ejected, PS314
(original exit 2) is not turned ON
within the specified time after
turning ON of PS313 (original exit
reverse detection).
4 - 36
Countermeasure
Machine response
RADF stops immedi-
Open the jam
ately.
access cover and
If there is a paper in
remove jammed
or after the copying
paper.
process, the machine
stops after completion
of copied paper
ejection.