Minolta DI750 - MANUAL SERVICE Service Manual page 254

Table of Contents

Advertisement

ERROR CODE LIST
Warning
Classification
code
Motor
F23-03
abnormality
F23-04
F23-05
F23-06
F23-07
F23-08
Causes
An M14 (cleaning blade) trouble
detection signal (excessive current)
is detected.
The drum READY1 signal (ready) is
not detected within 4 seconds after
turning ON of M2 (drum drive motor),
or the drum READY1 signal (not
ready) is not detected within 4
seconds after turning OFF of M2. At
this time, a trouble detection signal
(24V off) is detected.
The drum READY1 signal (ready) is
not detected within 4 seconds after
turning ON of M2 (drum), or the drum
READY1 signal (not ready) is not
detected within 4 seconds after
turning OFF of M2. At this time, an
M14 (cleaning blade) trouble
detection signal (blown fuse) is
detected.
The drum READY1 signal (ready) is
not detected within 4 seconds after
turning ON of M2 (drum), or the drum
READY1 signal (not ready) is not
detected within 4 seconds after
turning OFF of M2. At this time, no
trouble detection signal is detected.
The blade READY signal (ready) is
not detected within 5 seconds after
turning ON of the blade replacement
signal, or the blade READY signal
(not ready) is not detected within
5 seconds after turning OFF of
the blade replacement signal. At
this time, a trouble detection signal
(24V off) is detected.
The blade READY signal (ready) is
not detected within 5 seconds after
turning ON of the blade replacement
signal, or the blade READY signal
(not ready) is not detected within 5
seconds after turning OFF of the
blade replacement signal. At this
time, an M14 (cleaning blade) trouble
detection signal (blown fuse) is
detected.
4 - 50
Operation in case of
Estimated abnormal
warning occurrence
The machine stops
M2 (drum)
immediately and RL1
M14 (blade)
(main) is turned OFF.
DCDB (DC drive
board)
PRCB (printer
control board)
PS30 (blade 1)
PS31 (blade 2)
parts

Advertisement