Omron DEVICENET#05-2003 Operation Manual page 91

Drt1-com gt1 series devicenet multiple i/o terminal
Table of Contents

Advertisement

Transistor Output Units
Dimensions
80
Connector Cables
When a Transistor Output Unit (connector) is to be connected to an OMRON I/
O Block or a Connector-Terminal Block Conversion Unit, use the cables (sold
separately) listed in the following table.
Manufacturer
OMRON
Note V terminals and G terminals are internally connected. When the I/O power is
being supplied, the power can be supplied to the output devices from the V
and G connectors. Current supplied in this way, however, must be less than
2 A. If, instead of using the V and G connectors, the power supply is wired to
the terminal block as shown in the following diagram, the current supplied
must be less than 2.5 A.
Note The vertical center of the Unit is 4.9 mm lower than the center of the DIN
track. The Unit therefore extends downward 41.4 mm (including the mounting
hook) from the DIN track center.
Model number
XW2Z-@@@A
Connector-Terminal Block Conversion Unit
XW2B-20G4
XW2B-20G5
G79-@@@C
I/O Block
G7TC-OC16-1
G70D-SOC16-1
G70D-FOM16-1
G70A-ZOC16-4
M7F
Output Unit
I/O Block (example)
Approx. 59
Section 4-4
Corresponding device
Load