GT1-TS04T and GT1-TS04P Temperature Input Units
7. A message asking you to confirm will appear. Click Yes.
The calibration data stored in the EEPROM in the Temperature Input Unit
will be cleared.
8. When you have finished clearing the calibration data, click Close. The
Communications Unit and all I/O Units connected to it will be reset, and the
Unit will return to normal operating mode from Calibration Mode.
The Edit Unit Parameters Window for the Temperature Input Unit will be
displayed.
Note When clearing the calibration data stored in the Temperature Input
Unit, the data will be cleared and the default settings enabled at the
same time.