Relay Output Units
Dimensions
2
4
4-5-2
GT1-ROS16 Relay Output Unit with Miniature Relay
Output Specifications
92
160
Note The vertical center of the Unit is 4.9 mm lower than the center of the DIN
track. The Unit therefore extends downward 41.4 mm (including the mounting
hook) from the DIN track center.
Item
Number of outputs
Relay
Rated load (resistive load)
Rated thermal current
Maximum switching voltage
Maximum switching current
Minimum permissible load
Insulation resistance
Reference Data
For details about the Relay characteristics, refer to G6D-1A in the PCB Relays
Catalog (X033). The following table shows how the number of outputs that
can be ON simultaneously varies with the ambient temperature.
Approx. 82
Specifications
16 points
Miniature Relay (G6D-1A 24 VDC)
2 A at 250 VAC/2 A at 30 VDC
2 A
250 VAC/30 VDC
2 A
10 mA at 5 VDC (P level reference value)
1,000 M
Ambient temperature ( C)
Section 4-5
Approx. 68
60