Specifications - Omron CQM1H - PROGRAM Programming Manual

Programmable controllers; inner boards
Table of Contents

Advertisement

High-speed Counter Board
2-1-6

Specifications

Instructions
Related Control Bits, Flags, and Status Information
Word
Slot 1
Slot 2
IR 200
IR 232
IR 201
IR 233
IR 202
IR 234
IR 203
IR 235
IR 204
IR 236
IR 205
IR 237
IR 206
IR 238
IR 207
IR 239
IR 208:
IR 240:
Counter 1
Counter 1
IR 209:
IR 241:
Counter 2
Counter 2
IR 210:
IR 242:
Counter 3
Counter 3
IR 211:
IR 243:
Counter 4
Counter 4
66
Instruction
CTBL(63)
INI(61)
PRV(62)
Bits
00 to 15 Counter 1
PV (rightmost four digits) The PV of the high-speed counter on each
00 to 15
PV (leftmost four digits)
00 to 15 Counter 2
PV (rightmost four digits)
00 to 15
PV (leftmost four digits)
00 to 15 Counter 3
PV (rightmost four digits)
00 to 15
PV (leftmost four digits)
00 to 15 Counter 4
PV (rightmost four digits)
00 to 15
PV (leftmost four digits)
00 to 07 Comparison Results: Internal Output
Bits 00 to 07
08 to 11 Comparison Results: Bits for External
Outputs 1 to 4
12
Counter Operating Flag
13
Comparison Flag
14
PV Overflow/Underflow Flag
15
SV Error Flag
Used to register target or range comparison tables or used to start
comparisons for previously registered comparison tables. A table
can be registered and comparison started with separate instruc-
tions or the same instruction.
Used to start or stop comparison using registered comparison
table or used to change the PV of a high-speed counter.
Used to read the PV or status of a high-speed counter.
Name
port of the High-speed Counter Board is
stored after each cycle.
Note The form in which data is stored
Contains the bit pattern specified by oper-
and in CTBL(63) when a condition is satis-
fied.
Contains the bit pattern specified by oper-
and in CTBL(63) when a condition is satis-
fied.
0: Stopped
1: Operating
Indicates whether or not a comparison is in
progress.
0: Stopped
1: Operating
Indicates whether or not an overflow or
underflow has occurred.
0: Normal
1: Overflow or underflow has occurred
0: Normal
1: Setting error
Section 2-1
Meaning
Function
(BCD or hexadecimal) can be spec-
ified in the PC Setup (DM 6602 and
DM 6611).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cqm1h seriesSysmac cqm1h-cpu series

Table of Contents