■Add the sequential number of subscripts
• If files or folders with a same name exist in the SD memory card inserted in the high speed data logger module when
creating a subfolder, saved file, and accumulating file, a sequential number of subscripts is added.
Ex.
When a device value is added to the saved file name, and a file is switched without updating the device value
LOGGING
File switching occurrenc-
LOGGING
• If the setting is written to a file with a same name and updated when the logging file created in the past setting exists in the
SD memory card inserted in the high speed data logger module, a sequential number may be added to the accumulating
file or saved file.
Ex.
When the "LOG01" folder and the accumulating file "LOG01.CSV" exist in the inserted SD memory card, the setting name
under the same name as the setting type folder name and the accumulating file in the SD memory card are written and
updated
LOGGING
Writing settings
Update settings
LOGGING
1 FUNCTION
60
1.1 Data Logging Function
Setting type
folder
LOG01
es
LOG01
Setting type
folder
LOG01
LOG01
Subfolder
Saved file
20160116_
DATA
20160116_
DATA
Accumulating
file
LOG01.
CSV
LOG01.
CSV
LOG01
(1).CSV
(Created)
LOT_0001.
CSV
LOT_0001.
CSV
LOT_0001
(1).CSV