Mitsubishi Electric MELSEC iQ-R Series User Manual page 392

High speed data logger module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
SAVSWICTMNRECNU
M
SAVSWICTMNFILESIZ
E
SAVSWICTMNCONDTY
PE
SAVSWICTMNCOMPTY
PE
[SAVSWICTMNCOND_
START]
((Array area))
[SAVSWICTMNCOND_
END]
SAVNAMETYPE
SAVNAMESIMPNAME
SAVNAMESIMPDATE
SAVNAMESIMPTIME
APPX
390
Appendix 12 Setting Information File Format
Description
Number of records
File size
Single condition/Compound condition
Trigger type
(compound condition only)
Start of the array area (file switching
condition (each condition))
File switching condition (each
condition)
End of the array area (file switching
condition (each condition))
Saved file name setting
Add a name
Add a date
Add a time
Condition
Setting value
SAVSWICTMNTYPE is
100 to 100000
"RECORD"
SAVSWICTMNTYPE is
"MULTI", and
SAVSWICTMNTYPEREC is
"YES"
SAVSWICTMNTYPE is
10 to 16384
"FILESIZE"
SAVSWICTMNTYPE is
"MULTI", and
SAVSWICTMNTYPEFILE is
"YES"
Single condition
SINGLE
Compound condition
COMBINE
OR combine
OR
AND combine
AND
(Blank)
TRIGGERC
ONDITION
(Blank)
Simple setting
SIMPLE
Detailed setting
DETAILED
Selected
YES
Unselected
NO
Selected
YES
Unselected
NO
Selected
YES
Unselected
NO
Remarks
This item is not applied other than
the situations written on the left.
This item is not applied other than
the situations written on the left.
This item is not applied in the
following situation.
• SAVSWICTMNTYPE is
"RECORD", "FILESIZE", or
"TRIGGER"
• SAVSWICTMNTYPE is "MULTI",
and SAVSWICTMNTYPECOND is
"NO"
This item is not applied in the
following situation.
• SAVSWICTMNTYPE is
"RECORD", "FILESIZE", or
"TRIGGER"
• SAVSWICTMNTYPE is "MULTI",
and SAVSWICTMNTYPECOND is
"NO"
• SAVSWICTMNCONDTYPE is
"SINGLE"
This item is not applied in the
following situation.
• SAVSWICTMNTYPE is
"RECORD", "FILESIZE", or
"TRIGGER"
• SAVSWICTMNTYPE is "MULTI",
and SAVSWICTMNTYPECOND is
"NO"
This item is not applied in the
following situation.
• SAVSWICTMNTYPE is
"RECORD", "FILESIZE", or
"TRIGGER"
• SAVSWICTMNTYPE is "MULTI",
and SAVSWICTMNTYPECOND is
"NO"
This item is not applied in the
following situation.
• SAVSWICTMNTYPE is
"RECORD", "FILESIZE", or
"TRIGGER"
• SAVSWICTMNTYPE is "MULTI",
and SAVSWICTMNTYPECOND is
"NO"
This item is not applied in the
following situation.
• SAVNAMETYPE is "DETAILED"
This item is not applied in the
following situation.
• SAVNAMETYPE is "DETAILED"
This item is not applied in the
following situation.
• SAVNAMETYPE is "DETAILED"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-rd81dl96Melsec iq-sw1dnn-rdlutl

Table of Contents