Opening a Q-series high speed data logger module (QD81DL96)
project
Read a saved project.
Operating procedure
1.
Select [Project]  [Open Q-Series High Speed Data Logger Module (QD81DL96) project].
2.
Select the target file on the "Open Q Series High Speed Data Logger Module (QD81DL96) project" screen, then click the
[Open] button.
The settings to be changed are as follows:
Setting name
Network setting
Time synchronization setting
Access target CPU setting
FTP setting
Auto logging setting
Data logging setting
Event logging setting
Report setting
Event logging setting
*1 For only binary files.
Precautions
• Default values are set under the settings which do not exist in the MELSEC iQ-R series high speed data logger module
(RD81DL96) project.
• The own station CPU (access target CPU No. 01) series of access target CPU is changed to RCPU. Access target CPU
No. 02 to 64 series is changed to QCPU/LCPU. When the target setting of access target CPU No. 02 to 64 is CPU module
of MELSEC iQ-R series, change the series as necessary.
Changed content
A host name is changed to the default (RD81DL96).
This setting is changed to the default.
The series of own station CPU is changed to RCPU.
The series of other CPUs is changed to QCPU/LCPU.
Import source of global labels and device comments is disabled.
All the relations between the related data are canceled.
If the access target CPU name is duplicated, the suffixes ((1), (2), ...) will be
added to all the duplicated access target CPU names.
This setting is applied to the file transfer setting.
• FTP server name  Host name
• Login user name  User name
• Directory path  Path
This setting is applied to the logging operation setting.
The following data types of data and devices are changed:
• Word [unsigned]Word [Unsigned]/Bit String [16-bit]
• Double Word [Unsigned]  Double Word [Unsigned]/Bit String [32-bit]
"Add the sequential number" is specified in the simple setting of the saved file
name setting.
"_SNUM" is added at the end of the format in the detailed setting of the saved
file name setting.
The size of the character string will be changed as follows.
When size is even number: No change
When size is odd number: Changes to size + 1
If the file is in binary format, the option "Send a notifying e-mail when an event
occurs" of mail notification settings becomes disable.
2 HIGH SPEED DATA LOGGER MODULE CONFIGURATION TOOL
Applied setting
Network setting
Time synchronization setting
Access target CPU setting
Access target CPU setting
Data logging setting
Event logging setting
Report setting
Access target CPU setting
Data logging setting
Event logging setting
Report setting
File transfer setting
Logging operation setting
Data logging setting
Event logging setting
Report setting
Data logging setting
Event logging setting
Report setting
*1
Data logging setting
*1
Event logging setting
Report setting
Event logging setting
125
2.3 Project Management