■File transfer setting (FILETRANSFER.txt/csv)
Item
[FILETRANSFER_STAR
T]
((Array area))
[FILETRANSFER_END]
OPTRESEND
OPTRESENDBUFNUM
OPTNOTICOMP
• FILETRANSFER
Item
NO
NAME
TYPE
HOSTNAME
USRNAME
*1
PSWD
PATH
FTPPORT
TRNMODE
*1 A password is not output when exporting a file for security. The password need to be set in a CSV file when importing it.
APPX
380
Appendix 12 Setting Information File Format
Description
Start of the array area (file transfer
setting)
File transfer setting
End of the array area (file transfer
setting)
Resend when failed in transfer
Resend buffer size ([Count])
Notify transfer completion
Description
No.
File transfer setting name
Type
Host name
User name
Password
Path
FTP port number
Data transfer mode
Condition
Setting value
(Blank)
FILETRANS
FER
(Blank)
Selected
YES
Unselected
NO
OPTRESEND is "YES"
100 to 99999
Selected
YES
Unselected
NO
Condition
Setting value
1 to 16
Any character
string
FTP server
FTP
Shared folder
SHAREDFLD
Any character
string
Any character
string
Any character
string
Any character
string
TYPE is "FTP"
1 to 65535
PORT mode
PORT
PASV mode
PASV
Remarks
This item is not applied in the
following situation.
• OPTRESEND is "NO"
Remarks
This item is not applied in the
following situation.
• TYPE is "SHAREDFLD"
This item is not applied in the
following situation.
• TYPE is "SHAREDFLD"