Mitsubishi Electric MELSEC iQ-R Series User Manual page 119

High speed data logger module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Global label name
• Elementary data
The following table shows the display example when a global label is an elementary data and the data name example when
importing the data.
: Available, : Not available
Type
Global label name display example
Elementary data
GlobalLabel1
*1 Global labels can be imported only when  is marked for both importing into global labels and importing into data types.
*2 If the number of characters in the data name exceeds 32, the numbers beyond 32 are deleted from the beginning to match the number
to 32.
Ex.
• Array
The following table shows the display example when a global label is an array and the data name example when importing the
data.
: Available, : Not available
Type
Global label name display example
Array data
GlobalLabel2[0..1]
Array element
GlobalLabel2[1]
*1 Global labels can be imported only when  is marked for both importing into global labels and importing into data types.
*2 If the number of characters in the data name exceeds 32, the numbers beyond 32 are deleted from the beginning to match the number
to 32.
Ex.
• Structure
The following table shows the display example when a global label is a structure and the data name example when importing
the data.
: Available, : Not available
Type
Global label name display example
Structure data
GlobalLabel3
Structure element
Element1
Structure element [Array]
Element2[0..1]
Array element
Element2[1]
*1 Global labels can be imported only when  is marked for both importing into global labels and importing into data types.
*2 If the number of characters in the data name exceeds 32, the numbers beyond 32 are deleted from the beginning to match the number
to 32. If the number of characters in the data with an expanded structure exceeds 32, the element name is used as the data name. If the
number of characters in the element name exceeds 32, the numbers beyond 32 are deleted from the beginning to match the number to
32.
Ex.
Elementary data
Array data
Array element
Structure data
Structure element
Structure element [Array]
Array element
2 HIGH SPEED DATA LOGGER MODULE CONFIGURATION TOOL
*1
Import
Data name example
GlobalLabel1
*1
Import
Data name example
GlobalLabel2[1]
*1
Import
Data name example
GlobalLabel3.Element1
GlobalLabel3.Element2[1]
*2
*2
*2
117