Error code
Error name
1F52H to 1F5FH
Report source file error
1F62H to 1F65H
Report source file error
1F67H to 1F68H
Report source file error
1F6BH to 1F6EH
Report source file error
1F8AH
Directory creation error
1F8CH to 1F8FH
CSV file check error
1F90H to 1F97H
Binary file check error
1F98H
File check error
1F99H to 1F9AH
File open error
1F9BH
File read error
1F9CH
File write error
1F9DH
File read error
1FBCH
File write error
1FBDH
File creation error
1FC2H
CSV file open error
1FC3H
File check error
Error description
Data logging file to be output to the report file
cannot be found.
Data logging file to be output to the report file
cannot be found.
Data logging file to be output to the report file
cannot be found.
Data logging file to be output to the report file
cannot be found.
Failed to create the directory.
Failed to check the CSV file.
Failed to check the binary file.
Failed to check the file.
Failed to open the file.
Failed to read the file.
Failed to write the file.
Failed to read the file.
Failed to write the file.
Failed to create the file.
Failed to open the CSV file.
Failed to check the file.
Corrective action
• Configure and construct the system so that the
creation trigger occurs after the specified
number of records worth of data is saved in the
data logging file.
• Adjust the file switch timing for data logging.
• Check if the data logging file is being deleted
before the report is output.
• Replace the SD memory card.
• Configure and construct the system so that the
creation trigger occurs after the specified
number of records worth of data is saved in the
data logging file.
• Adjust the file switch timing for data logging.
• Check if the data logging file is being deleted
before the report is output.
• Replace the SD memory card.
• Configure and construct the system so that the
creation trigger occurs after the specified
number of records worth of data is saved in the
data logging file.
• Adjust the file switch timing for data logging.
• Check if the data logging file is being deleted
before the report is output.
• Replace the SD memory card.
• Configure and construct the system so that the
creation trigger occurs after the specified
number of records worth of data is saved in the
data logging file.
• Adjust the file switch timing for data logging.
• Check if the data logging file is being deleted
before the report is output.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Replace the SD memory card.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
• Delete unnecessary files on the SD memory
card to ensure free space.
• Replace the SD memory card.
4 TROUBLESHOOTING