Mitsubishi Electric MELSEC iQ-R Series User Manual page 221

High speed data logger module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

File transfer diagnostics
Display the results of transfer to a file server.
Window
Click the "File transfer diagnostics" from diagnostic items tree on the "Diagnostic" screen.
Displayed items
Item
Host name
Normal end
Error end
Error code
File resending buffering
Buffering number
status
Buffer usage rate
[Buffer clear] button
*1 "-" is displayed when "Resend when transfer failed" is not set in the optional setting of the file transfer setting.
*2 The maximum value is cleared when the high speed data logger module is turned OFF.
Description
Displays the host name.
Displays the number of times the file transfer has completed normally.
Displays the number of times the file transfer has completed abnormally.
Displays the newest error code of the file transfer.
Page 261 Error Code List
*1*2
Displays the number of units of data stored in the file resend buffer memory.
• Current value: Current number of buffering data/Set number of buffering data
• Maximum value: The maximum number of buffering data up to the present/Set number of
buffering data
*1*2
Displays the usage rate of the file resend buffer memory.
• Current value: Current usage rate
• Maximum value: Maximum usage rate up to the present
Clears the file resend buffer memory and cancels resending of all the files.