When "Saved file" is selected as the output source file, adjust processing so that the creation trigger occurs
after the file gets switched once.
By configuring the following settings, report files corresponding to data logging files one-to-one basis can be
created.
• Select "Saved file" in "Source file" on the "Data logging layout" screen of the report settings. (Page 199
Data logging layout)
• Select "At the data logging file switching" on the "Trigger condition setting" screen of report settings.
(Page 207 Creation trigger)
By setting the following settings, only trigger logging data before and after the rising of trigger condition can be
output to a report.
• Select "Trigger logging unit" in the [file] tab of the data logging settings.
• Select "Saved file" in "Source file" on the "Data logging layout" screen of the report settings. (Page 199
Data logging layout)
• Select "At the data logging file switching" on the "Trigger condition setting" screen of report settings.
(Page 207 Creation trigger)
■Specifying the leading cell
Operating procedure
1.
Click the input assistance button on the "Data logging layout" screen.
2.
Specify range of cells to layout data with the mouse, and click the [OK] button or the
While selecting the cell range, a screen with the title "RefEdit" may be displayed, but ignore it and continue to
select the leading cell.
■Source file
Select the file of which data logging records are to be output.
Select from accumulating file and saved file in SD memory card.
Accumulating file
2 HIGH SPEED DATA LOGGER MODULE CONFIGURATION TOOL
200
2.7 Report Setting
(New) 'Saved files'
File switching
Latest saved file
FileName_01
FileName_02
FileName_01
button.