Mitsubishi Electric MELSEC iQ-R Series User Manual page 204

High speed data logger module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

• Difference of report operation due to difference of source files
The following explains the report operation of each source file: "Saved file," "Accumulating file," and "Both."
The following shows how data is output when
-'100' is set to the number of records and "Chronological order (old  new)" is set to the output order in the data logging
layout setting
-50 records exist in the saved file and 30 records exist in the accumulating file when a report creation trigger is satisfied
Ex.
When the source file is "Saved file", 50 records worth of data are output to the report file from the latest saved file. (Because
the specified number of records is 100, the remaining 50 records become blank.)
50 records
100 records
Ex.
When the source file is "Accumulating file", 30 records worth of data are output to the report file from the accumulating file.
(Because the specified number of records is 100, the remaining 70 records become blank.)
30 records
100 records
2 HIGH SPEED DATA LOGGER MODULE CONFIGURATION TOOL
202
2.7 Report Setting
Report layout
Report layout
File output
Accumulating file
FileName_02
30 records
50 records
Latest saved file
File output
Accumulating file
FileName_02
30 records
50 records
Latest saved file
(New) 'Saved files'
FileName_01
(New) 'Saved files'
FileName_01