11
4. To fix the sump B1 , tighten the screws A1 by strictly
following the order indicated in the Fig. 11.83
(tightening torque of 25 Nm ).
5. Loosen the screw 1 again and tighten it to 25 Nm .
6. Apply a bead of approx. 2.5 mm of sealant ( Loctite
5660 ) inside the channel B3 of the oil sump B .
7. Position the oil sump B on the oil sump B1 flange at
the fixing holes (use the tool
8. Screw the screws A in the fixing holes.
9. To fix the sump B , tighten the screws A by strictly
following the order indicated in the Fig. 11.85
(tightening torque of 25 Nm ).
10. Loosen the screw 1 again and tighten it to 25 Nm .
EN
174
INFORMATION ABOUT OPTIONAL
COMPONENTS
ST_18
).
Fig. 11.83
Fig. 11.84
Fig. 11.85