Kohler KDI 1903M Workshop Manual page 16

Hide thumbs Also See for KDI 1903M:
Table of Contents

Advertisement

2
Type of fuel
High-pressure fuel injection pump
Fuel supply
Filtering surface
Degree of filtration
Maximum pressure at injection pump inlet
GENERAL INFORMATION
Lubrication
Circuit forced
Oil sump capacity (MAX)
Intervention pressure (MIN)
Maximum operating pressure
Degree of filtration
Filtering surface
GENERAL INFORMATION
Coolant
Water pump
Opening temperature
Stroke at 91°C
Liquid recirculation
GENERAL INFORMATION
Circuit rated voltage
External alternator (rated current)
Starter motor power
System electrical consumption, excluding:
heater, electric pump, electric fan, starter
motor
Indicator light operating temperature
EN
16
TECHNICAL INFORMATION
Fuel filter
cm
µm
bar
LUBRICATION CIRCUIT
UNIT OF
MEASURE
Fuel
Oil pressure switch
bar
Oil filter
bar
µm
cm
COOLING CIRCUIT
UNIT OF
MEASURE
Lt./min
Thermostatic valve
mm
Lt./h
ELECTRICAL SYSTEM - ELECTRIC FAN
UNIT OF
MEASURE
kW
Coolant temperature indicator light
Diesel UNI-EN590 - ASTM D975
STANADYNE - DB
Low pressure electric pump
2
KDI 1903 M
See
Lt.
8.9
2
KDI 1903 M
%
See
°C
KDI 1903 M
V
A
W
°C
2300
5
< 0.5
KDI 2504 M
Par. 2.4
Lobe pump
11,5
0.8±0.1
7.0
17±2
1744
KDI 2504 M
Par. 2.6
75
+79
7.50
9
KDI 2504 M
12
80
2
24
+100/+110

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdi 2504m

Table of Contents